FileFastq

File4DNFITUVPRD1
released

WARNING: Mapping bias was observed with this set of input reads.

   July 1st, 2019 at 2:40am

WARNING: Biased Read Mapping  


WARNING: The reads in this file displayed a mapping bias.

"Biased input" refers to input data sets that show unexpectedly large variations in read count over large chromosome domains that correlate with GC content as well as LAD/inter-LADs and early versus late DNA replication domains. They appear to be related to PCR bias during library construction. Input profiles typically are very similar from the same cell line between different experiments. TSA-Seq scores computed using input data from other experiments from the same cell line typically produce TSA-Seq scores significantly closer to TSA-Seq scores from replicate data sets which do not have biased input.


Properties  


File Format 
File Type 
Reads
General Classification 
Raw File
File Size 
1.72 GB

More Information


Quality Metric Summary 
Total Sequences 
28.4m
Sequence length 
35-100
Sequence length 
35-100
Overall Quality 
PASS
Link to Report 

Experiment Set